| Customization: | Available |
|---|---|
| Communication Mode: | Full-Duplex & Half-Duplex |
| Type: | Ethernet Switch |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Item | Specification |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.40 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 236.0 mm (1.72 in. x 17.40 in. x 9.29 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90 mm x 550 mm x 355 mm (3.54 in. x 21.65 in. x 13.98 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 2.98 kg (6.57 lb) |
Weight with packaging [kg(lb)] | 4.34 kg (9.57 lb) |
Typical power consumption [W] | 69.46 W |
Typical heat dissipation [BTU/hour] | 237.00 BTU/hour |
Maximum power consumption [W] | 93.39 W |
Maximum heat dissipation [BTU/hour] | 318.66 BTU/hour |
MTBF [year] | 32.56 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 41.42 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 27.74 dB(A) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 2 |
Redundant power supply | Not supported |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year.The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours.The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year. If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | DC built-in |
Rated input voltage [V] | -48 V DC to -60 V DC |
Input voltage range [V] | -38.4 V DC to -72 V DC |
Maximum input current [A] | 6 A |
Memory | 2 GB |
Flash memory | The physical space is 1 GB. You can run the display version command to view the actual available space. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Not supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | ±2 kV in differential mode; ±4 kV in common mode |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left and front, air exhaustion from right |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |
Package Size | 90.00cm * 60.00cm * 45.00cm |
Package Gross Weight | 12.000kg |