| Customization: | Available |
|---|---|
| Communication Mode: | Full-Duplex & Half-Duplex |
| Type: | Ethernet Switch |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Item | Specification |
Dimensions with packaging (H x W x D) [mm (in.)] | 175 mm x 650 mm x 550 mm (6.89 in. x 25.59 in. x 21.65 in.) |
Dimensions without packaging (H x W x D) [mm (in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the maximum distance from the protruding port on the front panel to the module handle on the rear panel): 43.6 mm x 442.0 mm x 446.5 mm (1.72 in. x 17.40 in. x 17.58 in.) |
Weight without packaging [kg (lb)] | 6.36 kg (14.02 lb) (excluding optical modules, power modules, and fan modules) |
Weight without packaging (full configuration) [kg (lb)] | 8.55 kg (18.85 lb) (including AC power modules and fan modules, excluding optical modules, calculated based on the heaviest model if multiple models are supported) |
Weight with packaging [kg (lb)] | 10.63 kg (23.43 lb) |
Weight with packaging (full configuration) [kg (lb)] | 12.82 kg (28.26 lb) |
Installation Type | Cabinet installation |
CPU | 4-core, 1.4 GHz |
Memory | DRAM: 8 GB |
NOR Flash | 64 MB |
SSD Flash | 4GB SSD |
USB | It can be used for log backup and USB-based deployment. This function is reserved. |
Power supply mode | ACDCHVDC |
Console port | RJ45 |
Downlink Service interface | 48 x 25GE SFP28/48 x 50GE SFP56 |
Uplink Service interface | 8 x 100GE QSFP28/8 x 200GE QSFP56 |
Service port supporting the stack function | Reserved function. This function is not enabled. |
RTC | Supported |
Typical power consumption [W] | 48 x 25G + 8 x 100G: 147 W (100% traffic load, copper cables on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 166 W (100% traffic load, short-distance optical modules on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 48 x 50G + 8 x 200G: 177 W (100% traffic load, copper cables on 24 x 50G ports, short-distance optical modules on 4 x 200G ports, normal temperature, dual AC power modules) |
Typical heat dissipation [BTU/hour] | 48 x 25G + 8 x 100G: 502 BTU/hr (100% traffic load, copper cables on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 566 BTU/hr (100% traffic load, short-distance optical modules on 24 x 25G + 4 x 100G ports, normal temperature, dual AC power modules) 48 x 50G + 8 x 200G: 604 BTU/hr (100% traffic load, copper cables on 24 x 50G ports, short-distance optical modules on 4 x 200G ports, normal temperature, dual AC power modules) |
Static power consumption [W] | 136 W |
Static heat dissipation [BTU/hour] | 464 BTU/hr |
Maximum power consumption [W] | 48 x 25G + 8 x 100G: 200 W (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 326 W (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) 48 x 50G + 8 x 200G: 227 W (100% traffic load, copper cables on 48 x 50G ports, short-distance optical modules on 8 x 200G ports, normal temperature, dual AC power modules) 328 W (100% traffic load, copper cables on 48 x 50G ports, long-distance optical modules on 8 x 200G ports, high temperature, dual AC power modules) |
Maximum heat dissipation | 48 x 25G + 8 x 100G: 682 BTU/hr (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules) 1112 BTU/hr (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules) 48 x 50G + 8 x 200G: 775 BTU/hr (100% traffic load, copper cables on 48 x 50G ports, short-distance optical modules on 8 x 200G ports, normal temperature, dual AC power modules) 1119 BTU/hr (100% traffic load, copper cables on 48 x 50G ports, long-distance optical modules on 8 x 200G ports, high temperature, dual AC power modules) |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | 600 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC1200 W DC power module: -48 V DC to -60 V DC; +48 V DC |
Input voltage range [V] | 600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC1200 W DC power module: -38.4 V DC to -72 V DC; +40 V DC to +57 V DC |
Maximum input current [A] | 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC)1200 W DC power module: 38 A (-48 V DC to -60 V DC); 38 A (+48 V DC) |
Rated output power [W] | 600 W AC&240 V DC power module: 600 W1200 W DC power module: 1200 W |
Certification | · Compliance with safety standards · Compliance with EMC standards · Compliance with environment and environmental protection standards |
Power supply surge protection [kV] | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 5 |
Redundant fans | The device supports 4+1 backup of fan modules that work in hot standby mode. If a single fan module fails, the device can work properly in a short period of time. To guarantee long-term operation of the device, you are advised to replace the failed fan module immediately |
Heat dissipation mode | Air cooling |
Airflow direction | Port-side air intake/port-side air exhaust, depending on the selected fan module and power module. |
Availability | 0.9999947936 |
MTBF [year] | 43.85 year |
MTTR [hour] | 2 hour |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Front-to-back airflow: Average: 52.8 dB(A); max: 58.7 dB(A) Back-to-front airflow: Average: 51.3 dB(A); max: 59.0 dB(A) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Front-to-back airflow: Average: 69.5 dB(A); max: 76.0 dB(A) Back-to-front airflow: Average: 70.2 dB(A); max: 75.6 dB(A) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage temperature [°C (°F)] | -40ºC to +70ºC (-40°F to +158°F) |
RTU License Supported | Yes. By default, 48 x 25GE ports can only work at the rate of 25 Gbit/s, and eight 100GE ports can only work at the rate of 100 Gbit/s. You can use the RTU license (BOM number: 88036EUQ) to increase the rate of 25GE ports to 50 Gbit/s and the rate of 100GE ports to 200 Gbit/s. |